Suchen

Certification and Accreditation

Here you’ll find our certificates and accreditation documents:

IMST – Quality Management

IMST – Prüfzentrum / Testcenter

 IMST – Prüfzentrum / Testcenter – Erweiterungen / Flexibilisierungen


AreaNorm / Method / Version
Title of Standard
Limitations
TK / ERMETSI EN 300 328 V2.2.2 (2019-07)Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
EMVDIN EN 55032: 2016-02 + Cor.1; VDE 0878-32: 2016-02Electromagnetic compatibility of multimedia equipment - Emission Requirements (CISPR 32:2015); German version EN 55032:2015

EMVDIN EN 55011: 2022-05Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement (CISPR 11:2015, mod. + A1:2016 + A2:2019); German version EN 55011: 2016 + A1:2017 + A11:2020 + A2:2021
3 m Measurement Distance only; No Devices of Class 2 above 1 GHz
EMVDIN EN 55014-1: 2018-08 + 2021-03/A11
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission (CISPR 14-1:2016 + A11:2020); Deutsche Fassung EN 55014-1:2017 + A11:2020
3 m Measurement Distance only;
EMVDIN EN 60335-1:2020-08
Safety electrical appliances for home use and similar purposes - Part 1: General requirements (IEC 60335-1: 2019, modified); German version EN 60335-1: 2019
Tests according to 19.11.4.1 - 19.11.4.6 only;
EMVDIN EN 61000-3-2:2019-12
EElectromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic currents (device input current <= 16 A per conductor) (IEC 61000-3-2: 2018); German version EN 61000-3-2: 2018
Tests for single-phased devices (max. 16 A, AC) only
EMVDIN EN 61000-3-3:2020-07, Cor.1: 2021-07
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection (IEC 61000-3-3:2013 + A1:2017); German version EN 61000-3-3:2013 + A1:2019
Tests for single-phased devices (max. 16 A, AC) only;
EMVDIN EN 61000-4-5:2019-03 + Cor.1:2021-04
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test (IEC 61000-4-5:2014 + A1:2017); German version EN 61000-4-5:2014 + A1:2017
No measurement at wired communication lines, no generator for pulses of the Form 10/700 μs, max. 16 A current;
EMVDIN EN 61000-4-11: 2021-10
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measuring method - Tests of the immunity to stress levels, short-term interruptions and voltage fluctuations (IEC 61000-4-11:2020 + COR1:2020); German version EN IEC 61000-4-11:2020 + AC:2020

EMVDIN EN 61000-6-1:2019-11
Electromagnetic compatibility (EMC) - Part 6-1: Foundation Standards - Immunity for living area, business and commercial areas and small businesses (IEC 61000-6-1: 2018); German version EN 61000-6-1: 2018

EMVDIN EN 61000-6-2:2019-11
Electromagnetic compatibility (EMC) - Part 6-2: Foundation standards - immunity for industrial sectors (IEC 61000-6-2: 2018); German version EN 61000-6-2: 2018

EMVDIN EN 61000-6-3:2022-06
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments (IEC 61000-6-3:2020); German version EN IEC 61000-6-3:2021
3 m Measurement Distance only;
EMVDIN EN 61000-6-4:2020-09
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments (IEC 61000-6-4:2006 + A1:2010); German version EN 61000-6-4:2007 + A1:2011
3 m Measurement Distance only;
EMVDIN EN 50121-3-2:2017-11 + A1:2020-11
Railway Applications - Electromagnetic Compatibility - Part 3-2: Railway Vehicles - Devices; German version EN 50121-3-2: 2016
Table 1, Part 1.2
EMVDIN EN 50121-4:2017-11 + A1:2020-11
Railway applications - Electromagnetic compatibility - Part 4: Funeral displays and immunity to signal and telecommunication devices; German version EN 50121-4:2016
No magnetic fields at 0 Hz, 300 A/m; 3 m measurement distance only
SARDIN EN IEC 62311:2020-12; VDE 0848-311:2020-12
Assessment of electrical and electronic devices relating to boundaries of exposure of persons in electromagnetic fields (0 Hz to 300 GHz) (IEC 62311: 2019); German version EN IEC 62311: 2020

EMVETSI EN 301489-1 V2.2.3 (2019-11)
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonized Standard for ElectroMagnetic Compatibility
3 m Measurement Distance only;
EMVETSI EN 301489-3 V2.1.1 (2019-03)
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz; Harmonized Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU
3 m Measurement Distance only;
EMVETSI EN 301489-17 V3.2.4 (2020-09)
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems; Harmonised Standard for ElectroMagnetic Compatibility
3 m Measurement Distance only;
IEC/IEEE 62209-1528: 2020
Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-worn wireless communication devices - Human models, instrumentation and procedures (Frequency range of 4 MHz to 10 GHz)

SARIEC/IEEE 62704-1: 2017-10
IEC/IEEE International Standard - Determining the peak spatial-average specific absorption rate (SAR) in the human body from wireless communications devices, 30 MHz to 6 GHz - Part 1: General requirements for using the finite-difference time-domain (FDTD) method for SAR calculations